Heat pump outdoor unit releasing steam during defrost mode on a cold Atlanta morning

Why Is My Heat Pump Steaming?

If your heat pump's outdoor unit is giving off steam or "smoke" on a cold morning, it's almost always normal: it's in defrost mode. When frost builds up on the outdoor coil, the heat pump briefly reverses itself to warm the coil and melt the ice, and that meltwater turns to steam. A normal defrost cycle lasts about 5 to 15 minutes, and then the unit goes back to heating your home. It's only a problem if the unit stays encased in ice, smells like burning, or keeps defrosting every few minutes. If you're not sure, call The Air Company of GA at 404-583-7788. We're family-owned, open 24 hours, and serve homes and businesses across Atlanta and the northern suburbs.

What Is Heat Pump Defrost Mode?

In heating mode, a heat pump pulls heat out of the outdoor air, even on chilly days. To do that, its outdoor coil runs colder than the air around it. On damp winter mornings in the 30s, which Atlanta gets plenty of, moisture in the air freezes onto that cold coil as frost. Frost blocks airflow and cuts the system's ability to heat your home.

To clear it, the heat pump's control board starts a defrost cycle:

  1. The reversing valve shifts the system into cooling mode for a few minutes, sending warm refrigerant through the outdoor coil.
  2. The outdoor fan usually stops, so the heat stays on the coil and melts the frost faster.
  3. Water drips off the coil, and some of it rises as steam that can look like smoke.
  4. Indoors, your backup heat (often electric heat strips) may turn on so you don't feel cool air from the vents.
  5. When the coil is clear, the valve shifts back with a "whoosh," the fan restarts, and normal heating resumes.

Signs Your Heat Pump Is Defrosting Normally

  • Steam or vapor rising from the outdoor unit for a few minutes, with no burning smell.
  • The outdoor fan stops while the compressor keeps running.
  • A loud whoosh or hiss when the cycle starts and ends. That's the reversing valve moving refrigerant.
  • A light layer of frost that clears on its own, then comes back later on very cold, humid days.
  • Water on the ground or pad around the unit after a cycle.
  • Your thermostat may show "Aux Heat" during defrost. Learn what that means in our guide to emergency heat vs. aux heat.

When Heat Pump Steam or Ice Means a Problem

Defrost should be short and should actually clear the coil. Call a technician if you notice any of these:

  • The unit is covered in solid ice (top, sides, or coil) for more than a couple of hours.
  • Real smoke or a burning smell instead of clean, odorless steam. Turn the system off and call right away.
  • Defrost runs every few minutes or never seems to stop.
  • The outdoor fan keeps running while the coil is iced over, meaning the unit may not be entering defrost at all.
  • Your home isn't keeping up with the thermostat, or your electric bill jumps because backup heat is running constantly.
  • Grinding, banging, or screeching noises from the outdoor unit. See our guide on strange HVAC noises.

Common Causes of a Heat Pump That Won't Defrost

  • A failed defrost sensor, thermostat, or control board
  • A sticking reversing valve
  • Low refrigerant from a leak (see signs of a refrigerant leak)
  • A dirty outdoor coil or a clogged indoor air filter restricting airflow
  • A broken outdoor fan motor
  • Water from a gutter or roof dripping onto the unit and freezing

If your heat pump also starts and stops more than it should, read why a heat pump short cycles.

What You Can Do Before You Call

  • Wait it out. Give a steaming unit 15 to 20 minutes. Most defrost cycles finish on their own.
  • Don't chip at the ice. Scraping or hitting the coil can puncture refrigerant lines and turn a simple repair into a big one.
  • Clear around the unit. Keep leaves, pine straw, and shrubs at least two feet away so air can flow.
  • Check the gutters. Make sure no water is pouring onto the top of the unit.
  • Change the indoor filter if it's dirty. Restricted airflow makes icing worse.
  • Switch to Emergency Heat if the outdoor unit is iced solid, so your home stays warm while you wait for service.

Heat Pump Repair Across Atlanta and the Northern Suburbs

Our NATE-certified technicians repair and maintain all major heat pump brands, and we're a Bryant dealer when it's time for a replacement. We serve Atlanta (including Buckhead, Midtown and Virginia Highland), Sandy Springs, Marietta, East Cobb, Smyrna, Vinings, Roswell, Alpharetta, Johns Creek, Duluth, Norcross, Peachtree Corners, Brookhaven, Dunwoody, Chamblee, Doraville, Tucker and Decatur. See our full service area.

A yearly tune-up catches weak defrost sensors, dirty coils and low refrigerant before the first hard freeze. Our service plan is $159 a year for your first system and $60 for each additional unit, and members get priority scheduling.

Heat pump iced over or acting strange? Call 404-583-7788 any time, day or night, or contact us online. The Air Company of GA, 10 Glenlake Parkway, Suite 130, Atlanta, GA 30328.

Heat Pump Defrost FAQ

Is it normal for my heat pump to steam in the winter?

Yes. Steam from the outdoor unit on a cold, damp day usually means the heat pump is in defrost mode, melting frost off its coil. It should stop within about 5 to 15 minutes. If you see real smoke or smell burning, turn the system off and call a technician.

How long should a heat pump defrost cycle last?

Most defrost cycles last about 5 to 15 minutes. How often they happen depends on outdoor temperature and humidity. If your unit defrosts every few minutes or stays iced for hours, the defrost controls or refrigerant charge likely need service.

Why does my heat pump blow cool air during defrost?

During defrost the heat pump briefly runs in cooling mode to warm the outdoor coil. Most systems turn on backup heat so the air stays warm, but you may notice slightly cooler air for a few minutes. If the air stays cold after defrost ends, schedule a repair.

Should I pour hot water on my frozen heat pump?

It's best not to. Never chip or scrape the ice, because that can damage the coil and refrigerant lines. Clear debris, check that no gutter water is dripping on the unit, switch your thermostat to Emergency Heat, and call a technician if the ice doesn't clear on its own.

Can I run my heat pump when it's iced over?

A light frost is normal and the unit will clear it. If the outdoor unit is covered in thick ice, switch the thermostat to Emergency Heat to protect the compressor and keep your home warm, then call for service.

Do you offer 24-hour heat pump repair in Atlanta?

Yes. The Air Company of GA is open 24 hours for residential and commercial heat pump repair across Atlanta, Sandy Springs, Marietta, Roswell, Alpharetta, Brookhaven, Decatur and nearby cities. Call 404-583-7788.